Fuji FRENIC-ACE AC Variable Frequency Drive FRN0012E2S-4GB, 7.5

In stock

The FRENIC-Ace is a high performance, full-featured Drive designed to suit a wide variety of applications including fans, pumps, specialized machinery and more. Equipped with 200 steps of customizable logic and PMAC motor control, the FRENIC-Ace provides compact, but powerful multi-rated specification solutions for virtually all AC drive applications and comes standard with an industry-leading 3-year warranty.

SPECIFICATIONS

Nominal Motor HP [kW] 7.5 Hp [5.5 kW] (ND & HD & HND)
5 Hp [3.7 kW] (HHD)
Rated Output Capacity kVA 9.1 kVA (ND)
8.5 kVA (HD & HND)
6.9 kVA (HHD)
Rated Output Voltage 3 Phase, 380-480 Volt (with AVR)
Rated Output Current 12 Amps (HD)
11.1 Amps (HD & HND)
9 Amps (HHD)
Rated Overload Capability 120 % of nominal current for 1 minute (ND & HND)
150 % of nominal current for 1 minute (HD)
150 % of nominal current for 1 minute or 200% of nominal current for 0.5 seconds (HHD)
Main Power Supply Input 3 Phase, 380 to 480 Volt, 50/60 Hz (With AVR)
Voltage / Frequency Variations Voltage: +10 % to -15%
Voltage Unbalance: 2% or less
Frequency: +5% to -5%
Rated Current Input without DC Reactor
[with DC Reactor] 16.8 Amps [10.1 Amps] (ND & HD & HND)
13 Amps [7.3 Amps] (HHD)
Required Power Supply Capacity 7 kVA (ND & HD & HND)
5.1 kVA(HHD)
Braking Torque 27 % (ND & HD & HND)
40 % (HHD)
DC Braking Starting frequency: 0.0 to 60.0 Hz
Braking Time: 0.0 to 30.0 Seconds
Braking Level: 0 to 60 % (ND),0 to 80 % (HD & HND), 0-100 % (HHD) of nominal current
Braking Chopper Built-In
Braking Resister Optional
Minimum Connectable Resistance 130 ?
DC Reactor Optional DCR4-5.5 (ND & HD & HND)
Optional DCR4-3.7 (HHD)
Cooling Fan Cooling
Optional Din Rail Mount RMA-E2-3.7
EMC Filter Optional
List Price $705.00
Dimensions 5.51" x 5.51" x 5.63"
Weight 4.2 lbs
Warranty 3 Years
ENVIRONMENTAL
Enclosure IP20, UL Open Type
UL Type 1 by Option Kit NEMA1-20E2-247
Ambient Temperature Standard (Open Type): -10 to +50 °C / 14 to 122 °F (HHD/HND)
NEMA 1/UL Type 1: -10 to+40 °C / 14 to 104 °F (HHD/HND)
Storage Temperature -25 to +65°C (-13 to 149 °F)
Humidity 5 to 95% Relative Humidity (without condensation)
Installation Location Indoors
Altitude <3,300ft (1,000m) 1000-1500m .97 Output Current Derating Factor 1500-2000m .95 Output Current Derating Factor 2000-2500m .91 Output Current Derating Factor 2500-3000m .88 Output Current Derating Factor CODES AND STANDARDS UL / cUL 508C C22.2 No.14 CE RoHs GOST-R KC EN / ISOc13849-1:2008 cat. 3/PL:e ELECTRICAL Control V/F Control V/F Control with Slip Compensation Dynamic Torque Vector Control V/F Control with Encoder (Optional) Vector Control with Encoder (Optional) PM Motor Sensorless Vector Control Output Stability Analog setting: +/-0.2% of maximum frequency Digital setting: +/-0.01% of maximum frequency (by keypad settings) Output Frequency Max 500Hz Speed Control Range 1:1500 IM Vector Control w/encoder 1:100 IM V/F w/encoder 1:10 PM Sensorless Vector Control Digital Inputs (7) X1 - X5, FWD, & REV Programmable, 60 selectable functions Analog Inputs (1) -0 to +10Vdc (1) -4 to 20mA Digital Outputs (1) From C Relay (2) Transistor Output, 78 Selectable Functions Analog Output: Selectable Type (2) 0 to 10Vdc or 4 to 20mA, 19 Selectable Output Signal Functions. RS-485 Connections (2) RJ45 Port Terminal Operator's Keypad with LED Display Indicating System Operation and Associated Value Conversion, Status of I/O, Operations and Alarms Keypad Indications Operations, Number of times unit placed in operation, Duration and kWh output 24Vdc Output Terminal 100mA Maximum Supply